SKU: 4JC-07HP

C&D JC-HP 8V 168Ah @ 8 Hr Rate SAN Ca 1.215 SPG Flooded VLA Battery

$1,296.42
Pre-order
OUT OF STOCK
ONLY %number% LEFT

Other models in this line

  • Quick Facts

  • Documentation

  • Services

Battery type

Flooded Lead Calcium (PbCa)
Title
Title

operating environment

Indoor, Outdoor Controlled

CAPACITY

168Ah
Title
Title

certifications & compliances

TAA Compliant, BAA Compliant

design life & warranty

20 Years Design Life
1 Year Full - 19 Pro-Rata Warranty
Title

industries

Data Center & UPS, Telecom, Utility, Petrochemical

Specifications

view more in-depth details on c&d’s pure lead max battery models

Title

safety

view more in-depth details on safety features and certifications for c&d’s pure lead max battery models

auditing & safety

compliance packages

spill containment systems

spill clean up / remediation

Title

rentals & emergency

container rentals

battery rentals

emergency rentals & response

installation

batteries

c0 / msc / cell site

power equipment

Title

microgrid design

feasibility assessment & budgeting

system design, install, & maintenance

operations & optimization

technical

capacity & acceptance Testing

battery & equipment commissioning

maintenance

Title

recycling

batteries - remove, replace, recycle

approved transport & smelting

DJ-HP

4JC-07HP FLOODED C&D BATTERIES

4JC-07HP JC-HP flooded batteries are engineered to provide superior performance and reliability over the life of the product. These batteries are designed using proprietary techniques and quality components and materials for reduced maintenance and extended battery life. The C&D 4JC-07HP flooded batteries are high-performance, space-saving batteries for UPS, Telcom and switchgear and control. The unique jar design facilitates faster and safer installation. The reliable tongue and groove jar-to-cover seal design provides increased adhesive coverage area offering unprecedented seal integrity during service.

4JC-07HP FEATURES AND BENEFITS

RELIABILITY
• Reliable tongue and groove jar-to-cover seal design provides increased adhesive coverage area — offering unprecedented seal integrity during service
• Top suspended positive plate design allows free downward growth without pressure on jar, cover, or post seal — extending reliability and product life
• Recessed vent area to collect water and acid spills, keeping them away from posts and cover — lowering maintenance and clean-up costs
• Wrapped separator design extends cycle life — improving product reliability
• Enhanced post seal design allows growth without transmitting forces to cover


SAFE OPERATION
• Self extinguishing features (LOI >32) of flame retardant (FR) cover and jar material — providing added protection
• Low evaporation, flame arrestor vents protect against an external source igniting hydrogen gas within the cells —improving safety


COST SAVINGS
• Unique jar design facilitates faster and safer installation
• Compact, optimized product size nets up to 40% floor space reduction — saving valuable space
• C&D capacity tests every DJ-HP battery to 100% of 1 hr published rating which ensures 100% capacity out-of-the-box at this rate (no need to field cycle the batteries to reach rated capacity) saving time and money for users


EASY MAINTENANCE
• All posts and connectors reside above the jar cover
• Individual posts allow monitoring of individual cell performance in a multi-cell container
• Individual posts use standard lead-plated copper connectors decreasing connection resistance
• Optional terminal and connector cover available (P/N RD00907-“L”)

4JC-07HP SPECIFICATIONS

  • Recommended Float Voltage: 2.20 - 2.25 vpc for 1.215 s.g. and 2.22 - 2.27 vpc for 1.250 s.g.
  • Electrolyte: Sulfuric acid, 1.215 s.g. standard, 1.250 s.g. optional
  • Container: Thermoplastic, transparent, (SAN)
  • Separator: U-wrapped, microporous with fibrous glass mat
  • Cover: High impact, flame-retardant PVC with tongue-and-groove seal Flammability ratings: UL94-V0; ASTM D-635 self extinguishing
  • Safety Vent Systems: Flame-arrester/low-evaporation type
  • Terminals: Rectangular lead post: 2 per cell
  • Available in Poly and San

4JC-07HP APPLICATIONS

• Telecom
• UPS
• Electric Utility Substations
• Manufacturing Facilities
✛ Assembly Lines
✛ Process Controls
✛ Communication Systems
• Petrochemical Processing Plants
• Pipelines
• Emergency Systems
• Railway Signals

Power Storage Solutions Installation and Service for 4JC-07HP

We understand that data centers are heavily reliant on batteries for backup power. We also understand that batteries must be redundant and if only one battery in your UPS configuration is not performing; it compromises your overall backup power. Our experience and our focus is to know the batteries and their implication for your operation. To determine the perfect solution, we will partner with you, analyze your critical power needs and construct the backup power solution that will perform as designed.


We can remove and recycle your old battery system then install, properly set up and test your new system. We have been installing stationary batteries for over 20 years. We have the experience, equipment and capabilities to safely perform this type of work.


Routine maintenance ensures your UPS equipment stays reliable, improving your UPS’s overall performance and extending their useful life. Service plans allow customers to be proactive; providing opportunity to detect potential points of failure preventing expensive problems.

Power Storage Solutions Installation and Service for 4JC-07HP

We understand your operations are heavily reliant on batteries for backup power.  Our experience and our focus is to know the batteries and their implication for your operation. To determine the perfect solution, we will partner with you, analyze your critical power needs and construct the backup power solution that will perform as designed.


Routine maintenance ensures your equipment stays reliable, improving your overall performance and extending their useful life. Service plans allow customers to be proactive; providing opportunity to detect potential points of failure preventing expensive problems.


When ordering new batteries, also remember to properly recycle your old lead batteries. Federal and state regulations require lead-acid batteries be recycled. Power Storage Solutions’ nationwide service organization can arrange pickup, transportation to and recycling at any one of our company affiliated smelters. 


For More Information from C&D Technologies Website: JC-HP

Similar Products

Related Products

Related
Articles