SKU: 3OGI280

EnerSys PowerSafe OGi 6V 281Ah @ 8 Hr Rate 1.24 SPG ABS Flooded VLA Battery

$955.38
Pre-order

Other models in this line

3OGI200

$770.77

Pre-order

3OGI225

$832.31

Pre-order

3OGI250

$900.00

Pre-order

  • Quick Facts

  • Documentation

  • Services

Battery type

Rod Flooded Lead Antimony (PbSE)
Title
Title

CAPACITY

Title
Title

design life & warranty

15 Years Design Life
1 Year Full Warranty
Title

operating environment

Title

certifications & compliances

Title

industries

Utility, Petrochemical

Specifications

view more in-depth details on applications & specifications

EnerSys PowerSafe OGi Installation Instruction Manual.pdf
EnerSys PowerSafe OGi Battery Specification Sheet.pdf
EnerSys PowerSafe OGi Warranty.pdf
EnerSys PowerSafe OGi Battery Range Summary.pdf
Title

safety

view more in-depth details on safety features & certifications 

EnerSys PowerSafe OGi Safety Data Sheet.pdf

auditing & safety

compliance packages

spill containment systems

spill clean up / remediation

Title

rentals & emergency

container rentals

battery rentals

emergency rentals & response

Title

installation

batteries

c0 / msc / cell site

power equipment

Title

microgrid design

feasibility assessment & budgeting

system design, install, & maintenance

operations & optimization

Title

technical

capacity & acceptance Testing

battery & equipment commissioning

maintenance

Title

recycling

batteries - remove, replace, recycle

approved transport & smelting

EnerSys 3OGi280 POWERSAFE® OGi BATTERIES

EnerSys 3OGi280 PowerSafe® features vented lead acid (VLA) technology built to handle demanding duty cycles, making them a reliable, safe and durable power solution for a range of utility applications. The rod plate composition in 3OGi280 PowerSafe®  batteries have a high energy density design that supports long life. Their low antimony alloy grid cuts water consumption and associated maintenance costs, while the high integrity terminal and jar design maximizes operational safety and inhibits electrolyte leaks. PowerSafe® OGi batteries also feature raised posts to ease maintenance and NERC measurement requirements, plus a clear Styrene Acrylonitrile (SAN) jar that allows for easy inspection of the plates and electrolyte level. 

3OGi280 POWERSAFE® FEATURES AND BENEFITS

• Capacity range 60 to 280 Ah
• High energy design with space efficient foot prints
• 100% Capacity at delivery
• Rod style low-antimony alloy flat plate positive grid suited for switchgear, utility and telecom applications
• Proven grommet terminal seal
• 20 year design life @77˚F (25˚C) in float applications
• Manual maintenance readings can be taken on individual cells to fulfil NERC™ requirements

3OGi280 POWERSAFE® APPLICATIONS

• Medical Standby Power

3OGi280 POWERSAFE® CONSTRUCTION

• Rod style positive flat plate grid
• Pasted flat plate negative grid optimized for maximum performance
• Special microporous separator with glass fiber mat
• Durable, high impact resistant, clear SAN jar allows visual inspection of plates and electrolyte
• Opaque ABS (Acrylonitrile Butadiene Styrene) lid
• Dilute sulphuric acid electrolyte - 1.240 Specific Gravity at maximum level line
• Leak resistant safety pole post design with brass insert

3OGi280 POWERSAFE® INSTALLATION AND OPERATION

• Footprint offers extremely efficient space utilization
• Equipped with flame arrestor vent plugs for safe operation
• Encapsulated connectors and bolts offer added safety
• Raised posts allow easy parameter measurements without disassembly
• Low antimony grid alloy greatly reduces watering intervals compared to antimony grid
• Operating temperature range: 14°F (-10°C) to 113°F (45°C) Recommended temperature range: 68°F (20°C) to 86°F (30°C)

3OGi280 POWERSAFE® STANDARDS

• Compliant with IEC 60896-11
• Compliant with DIN 40737-3

Power Storage Solutions Engineering Services for 3OGi280

Our engineering team can help you quickly calculate many values essential for the proper selection of standby battery products We provide expert sizing analysis you need to properly size and select the proper battery.  Let our Battery Sizing Specialist ensure you select the correct product for your telecommunications applications.


This includes the ability to:  Select batteries based on complex step loads and generate IEEE-485 Sizing Work Sheets.  Select batteries based on constant current loads. Select batteries based on constant power loads. View and customize rating tables. Perform battery run time analysis.

Power Storage Solutions Installation and Service for 3OGi280

We understand that data centers are heavily reliant on batteries for backup power. We also understand that batteries must be redundant and if only one battery in your UPS configuration is not performing; it compromises your overall backup power. Our experience and our focus is to know the batteries and their implication for your operation. To determine the perfect solution, we will partner with you, analyze your critical power needs and construct the backup power solution that will perform as designed.


We can remove and recycle your old battery system then install, properly set up and test your new system. We have been installing stationary batteries for over 20 years. We have the experience, equipment and capabilities to safely perform this type of work.


Routine maintenance ensures your UPS equipment stays reliable, improving your UPS’s overall performance and extending their useful life. Service plans allow customers to be proactive; providing opportunity to detect potential points of failure preventing expensive problems.


When ordering new batteries, also remember to properly recycle your old lead batteries. Federal and state regulations require lead-acid batteries be recycled. Power Storage Solutions’ nationwide service organization can arrange pickup, transportation to and recycling at any one of our company affiliated smelters. 


For More Information from EnerSys Website: EnerSys PowerSafe OGi