SKU: 12HX680F-FR

EnerSys DataSafe HX 12V 680WPC @ 15 Min 1.3 SPG POLY-FR VRLA Battery

$664.15
Pre-order
OUT OF STOCK
ONLY %number% LEFT

Other models in this line

12HX100FR

$129.02

Pre-order

12HX135BFR

$145.60

Pre-order

12HX135RFR

$145.60

Pre-order

12HX150E

$158.11

Pre-order

12HX150FR

$158.11

In Stock

12HX205FR

$197.48

Pre-order

12HX25FR

$32.74

Pre-order

12HX300FR

$222.80

In Stock

12HX330FR

$248.15

In Stock

12HX35FR

$37.34

Pre-order

12HX400FR

$266.28

In Stock

12HX505FR

$356.37

In Stock

12HX50FR

$68.52

Pre-order

12HX540FR

$375.58

In Stock

12HX80FR

$84.54

Pre-order

  • Quick Facts

  • Documentation

  • Services

Battery type

AGM (VRLA)
Title
Title

operating environment

CAPACITY

680WPC @ 15 Min
Title
Title

certifications & compliances

design life & warranty

10 Years Design Life
4 Year Full Warranty
Title

industries

Data Center & UPS

Specifications

view more in-depth details on c&d’s pure lead max battery models

DataSafe HX 6V & 12V Top Terminated Battery Installation & Maintenance Manual.pdf
UPS Product Guide.pdf
Standby Power Product Overview.pdf
12HXFT Installation and Operation.pdf
12HX FT Battery Cabinet.pdf
DataSafe HX 6V & 12V Top Terminated Battery Range Summary.pdf
DataSafe HX Cabinet Range Summary.pdf
Q-206490.pdf
882920.pdf
Title

safety

view more in-depth details on safety features and certifications for c&d’s pure lead max battery models

SDS853024Non-SpillableLeadAcidBattery-Reserve&PortableProductsOnly.pdf

auditing & safety

compliance packages

spill containment systems

spill clean up / remediation

Title

rentals & emergency

container rentals

battery rentals

emergency rentals & response

installation

batteries

c0 / msc / cell site

power equipment

Title

microgrid design

feasibility assessment & budgeting

system design, install, & maintenance

operations & optimization

technical

capacity & acceptance Testing

battery & equipment commissioning

maintenance

Title

recycling

batteries - remove, replace, recycle

approved transport & smelting

12HX680F-FR DATASAFE®

EnerSys 12HX680F-FR DATASAFE® HX BATTERIES

The 12HX680F-FR DataSafe® battery offers the convenience and lower maintenance costs of a front terminal battery design but still delivers the power required
for demanding high rate UPS applications. Featuring valve regulated lead acid (VRLA) technology, DataSafe® HX batteries offer superior solutions for a range of uninterruptible power supply (UPS) and IT applications. The 12HX680F-FR DataSafe® batteries combine several select design features to maximize reliability and service life while ensuring high power, low maintenance performance.

12HX680F-FR DATASAFE® SPECIFICATIONS

• Short Circuit Current: 5960 Amperes
• Float Voltage: @ 77°F (25°C) 2.25 - 2.28 Volts per cell)
• Freshening (Equalization) Voltage: 2.4 Volts per cell*
• Maximum Discharge Current: 1200 Amperes
• Maximum Charging Current: 40 Amperes
• Self Discharge: @ 77°F (25°C) Less than 10% after 90 days
• Recommended Operating Temperature: 68°F (20°C) to 77°F (25°C)
• Container and Cover Materials: UL94 Flame Retardant Polypropylene
• Front Access Terminals; 5/16-18 UNC Thread

12HX680F-FR DATASAFE® FEATURES AND BENEFITS

• Smaller footprint per kilowatt.
• Simplifies installation.
• Improves reliability.
• Complete front access.
• Eliminates wasted headspace found in typical 12V top terminated designs.
• Easy and safer front terminal access simplifies maintenance.
• No costly slide out trays required to obtain terminal access.

12HX680F-FR DATASAFE® APPLICATIONS

• Industrial UPS
• Alarm & Security Systems
• Emergency Lighting
• Public Safety Networks
• Surveillance & Security
• Traffic & Intelligent Transportation Systems (ITS)
• Data Centers

12HX680F-FR DATASAFE® INSTALLATION AND OPERATION

• Batteries come standard with a stainless steel hardware package. The hardware package includes (2) each 5/16-18 UNC bolts, flat washers and lock washers. Additional accessories are available for purchase.

12HX680F-FR DATASAFE® TRANSPORTATION

• Exempt from DOT, IATA & IMDG Transportation Restrictions when properly identified and packaged.

Power Storage Solutions Installation and Service for 12HX680F-FR DATASAFE®

We understand that data centers are heavily reliant on batteries for backup power. We also understand that batteries must be redundant and if only one battery in your UPS configuration is not performing; it compromises your overall backup power. Our experience and our focus is to know the batteries and their implication for your operation. We will partner with you, analyze your critical power needs and construct the backup power solution that will perform as designed


We can remove and recycle your old battery system then install, properly set up and test your new system. We have been installing stationary batteries for over 20 years. We have the experience, equipment and capabilities to safely perform this type of work


Routine maintenance ensures your UPS equipment stays reliable, improving your UPS’s overall performance and extending their useful life. Service plans allow customers to be proactive; providing opportunity to detect potential points of failure preventing expensive problems.


When ordering new batteries, also remember to properly recycle your old lead batteries. Federal and state regulations require lead-acid batteries be recycled. Power Storage Solutions’ nationwide service organization can arrange pickup, transportation to and recycling at any one of our company affiliated smelters.


For More Information from EnerSys Website: EnerSys Datasafe HX

Similar Products

Related Products

Related
Articles