{"product_id":"enersys-powersafe-gu-2v-3900ah-8-hr-rate-1-215-spg-pvc-fr-flooded-vla-battery","title":"EnerSys PowerSafe GU 2V 3900Ah @ 8 Hr Rate 1.215 SPG PVC-FR Flooded VLA Battery","description":"\u003ch2\u003eEnerSys GU-45 POWERSAFE® GU BATTERIES\u003c\/h2\u003e\u003cp\u003ePowerSafe® GU-45 batteries offer field-tested performance that meets industry requirements for long life and less maintenance. PowerSafe® GU batteries feature copper inserts in the posts maintain excellent short duration high-current performance, while individual posts enable individual cell monitoring, The PowerSafe® GU-45 also feature the Slide-Lock™ post seal that allows for natural plate growth over time without damaging the seal. PowerSafe® GU batteries are engineered for power industry demands and feature calcium plates for maximized performance in long distance applications. Extra thick positive grids and high temperature resistance make the PowerSafe® GU series one of the most rugged on the market.\u003c\/p\u003e\u003ch3\u003eGU-45 POWERSAFE® FEATURES AND BENEFITS\u003c\/h3\u003e\u003cp\u003e• Capacity Range: 930Ah - 3900Ah\u003cbr\u003e• Flat Plate construction-Calcium grid alloys. Well suited for long duration, float applications.\u003cbr\u003e• Largest single cell battery (up to 3900Ah) in a clear flame retardant jar.\u003cbr\u003e• Optional Flame Retardant (UL94-VO\/L.O.I. 32%) container.\u003cbr\u003e• Slide Lock™ Post Seal allows natural plate growth without degrading post seal.\u003cbr\u003e• Innovative tongue and groove jar-to-cover seal.\u003cbr\u003e• Configurable with plates either parallel (optimize footprint) or perpendicular (inspection of the element) to rack support rails.\u003c\/p\u003e\u003ch3\u003eGU-45 POWERSAFE® APPLICATIONS\u003c\/h3\u003e\u003cp\u003e• Central Offices\/ Switching Centers\u003c\/p\u003e\u003ch3\u003eGU-45 POWERSAFE® Specifications\u003c\/h3\u003e\u003cp\u003e• PLATES THICKNESS:\u003cbr\u003e\u003c\/p\u003e\u003cblockquote class=\"shift\" style=\"margin-left: 40px;\"\u003ePositive: 0.30 in\/7.6 mm\u003c\/blockquote\u003e\u003cblockquote class=\"shift\" style=\"margin-left: 40px;\"\u003eNegative: 0.20 in\/5.1 mm\u003c\/blockquote\u003e• PLATE DIMENSIONS: Height Width\u003cbr\u003e\u003cblockquote class=\"shift\" style=\"margin-left: 40px;\"\u003ePos: 17.6 in\/447 mm 12.7 in\/323 mm\u003c\/blockquote\u003e\u003cblockquote class=\"shift\" style=\"margin-left: 40px;\"\u003eNeg: 17.6 in\/447 mm 12.7 in\/323 mm\u003c\/blockquote\u003e• SEDIMENT SPACE: 1.32 in\/34 mm\u003cbr\u003e• ELECTROLYTE OVER PLATES: 3.40 in\/86 mm\u003cbr\u003e• CONTAINER: Styrene Acrylonitrile Copolymer, GU-09 to GU-45 Optional flame retardant (UL94-VO\/L.O.I. 32%) PVC, GU-15 to GU-45 Optional flame retardant (UL94-VO\/L.O.I. 32%) PC, GU-09 to GU-13\u003cbr\u003e• COVER: Flame Retardant PVC, UL94-VO\/L.O.I. 32%\u003cbr\u003e• SEPARATORS: Microporous rubber\u003cbr\u003e• RETAINERS: “Vitrex”- glass fiber\u003cbr\u003e• POST TYPE: Cast Lead Posts,\u003cbr\u003e\u003cblockquote class=\"shift\" style=\"margin-left: 40px;\"\u003eGU-9 through GU-13 Single Post\u003c\/blockquote\u003e\u003cblockquote class=\"shift\" style=\"margin-left: 40px;\"\u003eGU-15 through GU-45 Double Posts\u003c\/blockquote\u003e• POST SEAL TYPE: Slide-Lock™\u003cbr\u003e• PLATE SUSPENSION TYPE:\u003cbr\u003e\u003cblockquote class=\"shift\" style=\"margin-left: 40px;\"\u003ePositive: Bridge hung\u003c\/blockquote\u003e\u003cblockquote class=\"shift\" style=\"margin-left: 40px;\"\u003eNegative: Bottom supported\u003c\/blockquote\u003e• ELECTROLYTE WITHDRAWAL TUBE: One per cell\u003cbr\u003e• VENT TYPE: Flame Arrestor, Fused Alumina\u003cbr\u003e• FLOAT VOLTAGE SETTING: Acceptable min\/max: 2.17\/2.26Vpc Recommended: 2.25Vpc\u003cbr\u003e• SPECIFIC GRAVITY: 1.215 at 77°F (25°C)\u003cbr\u003e• BOLT CONNECTORS: Stainless steel, standard English measure, hex-head\u003cbr\u003e• INTERCELL CONNECTORS: Lead-plated copper\u003cp\u003e\u003c\/p\u003e\u003ch3\u003e\u003cspan\u003ePower Storage Solutions Engineering Services for GU-45\u003c\/span\u003e\u003c\/h3\u003e\u003cp\u003eOur engineering team can help you quickly calculate many values essential for the proper selection of standby battery products We provide expert sizing analysis you need to properly size and select the proper battery.  Let our Battery Sizing Specialist ensure you select the correct product for your telecommunications applications.\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eThis includes the ability to: \u003c\/strong\u003e Select batteries based on complex step loads and generate IEEE-485 Sizing Work Sheets.  Select batteries based on constant current loads. Select batteries based on constant power loads. View and customize rating tables. Perform battery run time analysis.\u003c\/p\u003e\u003ch3\u003e\u003cspan\u003ePower Storage Solutions Installation and Service for GU-45\u003c\/span\u003e\u003c\/h3\u003e\u003cp\u003eWe understand that data centers are heavily reliant on batteries for backup power. We also understand that batteries must be redundant and if only one battery in your UPS configuration is not performing; it compromises your overall backup power. Our experience and our focus is to know the batteries and their implication for your operation. To determine the perfect solution, we will partner with you, analyze your critical power needs and construct the backup power solution that will perform as designed.\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003eWe can remove and recycle your old battery system then install, properly set up and test your new system. We have been installing stationary batteries for over 20 years. We have the experience, equipment and capabilities to safely perform this type of work.\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003eRoutine maintenance ensures your UPS equipment stays reliable, improving your UPS’s overall performance and extending their useful life. Service plans allow customers to be proactive; providing opportunity to detect potential points of failure preventing expensive problems.\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003eWhen ordering new batteries, also remember to properly recycle your old lead batteries. Federal and state regulations require lead-acid batteries be recycled. Power Storage Solutions’ nationwide service organization can arrange pickup, transportation to and recycling at any one of our company affiliated smelters. \u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003eFor More Information from EnerSys Website:\u003ca href=\"https:\/\/www.enersys.com\/en\/products\/batteries\/powersafe\/powersafe-g\/\"\u003e EnerSys PowerSafe GU\u003c\/a\u003e\u003c\/p\u003e","brand":"ENERSYS (STANDBY POWER)","offers":[{"title":"Default Title","offer_id":48024427331816,"sku":"GU-45PVC","price":4386.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/2159\/9976\/files\/75759c76-c8fb-f011-837b-12b451dc4669_GU-45PVC_..png?v=1769563479","url":"https:\/\/pwrstoragesolutions.com\/products\/enersys-powersafe-gu-2v-3900ah-8-hr-rate-1-215-spg-pvc-fr-flooded-vla-battery","provider":"Power Storage Solutions","version":"1.0","type":"link"}