The new Pure Lead Max (PLM) Batteries are C&D’s longest lasting VRLA battery for UPS systems and has an industry-leading 8-year warranty. Thanks to patented pure lead alloy and catalyst technology, Pure Lead Max can reduce total cost of ownership by offering a sustainable, single-replacement for a 15-year UPS system. PLM is the safe choice for your back up needs.

*Assumes a replacement cycle based on standard warranty of 3 years for VRLA and 5 years for PLP over a 15-year UPS life.

 KEY FEATURES & BENEFITS

  • 16 year design life
  • Storage capability of 2 years at 25˚C (77˚F) with minimum upkeep
  • Eurobat - very long life
  • Catalyst technology extends service life
  • MSE's Advanced proprietary paste processing for high active material utilization resulting in low float current
  • Patented Long-Life Alloy in the grids to minimize grid growth, reduce gassing, and extend battery life
  • Reduces footprint by up to 28% and battery quantity by up to 40% vs leading competitor
  • Up to 38% less maintenance costs based on recommended maintenance schedule
  • 98% recyclable and manufactured with up to 80% of recycled materials
  • Available in both Top terminal and TFA (True Front Access) formats
  • TFA design maximizes energy density and minimizes internal resistance by providing a direct connection from the plates to the terminals
  • Patented UL recognized flame-arresting vents in each cell for safety
  • Thermally welded and helium leak tested case-to-cover bond ensures a robust leak proof seal
  • Can be operated in any orientation
  • Published rates down to 1 minute

BATTERY TYPE

  • VRLA

UPS12-1005PLMF SPECIFICATIONS

  • Operating Temperature Range w/ Temperature Compensation- Discharge: -40ºF (-40ºC) to +160ºF (71ºC). Charge: -10ºF (23ºC) to +140ºF (60ºC)
  • Nominal Operating Temperature Range: +74ºF (23ºC) to +80ºF (27ºC)
  • Recommended Maximum Charging Current Limit: C20/5 amperes (20 hr. rate)
  • Float Charge Voltage: 13.65 ± 0.15 VDC average per 12V unit
  • Maximum AC Ripple (Charger): 0.5% RMS or 1.5% P-P of float charge recommended for best results. Max voltage allowed = 1.4% RMS (4% P-P) Max current allowed = C/20 (20 hr. rate)
  • Self Discharge: Batteries can be stored up to 24 months at +77ºF (+25ºC) before freshening charge is required. Batteries stored at temperatures greater than +77ºF (+25ºC) will require recharge sooner than batteries stored at lower temperatures.
  • Equalize and Cycle Service Charge Voltage: 14.40 to 14.80 VDC average per 12V unit @ +77ºF (+25ºC)
  • Terminal - Inserted: Top terminal batteries: 1/4-20 UNC Bolt. Front terminal batteries: 1/4-20 UNC Bolt / Insert (M8)
  • Terminal Hardware Initial Torque - Inserted Terminal: Top Terminal Batteries: 110 in.-lbs (12.4 N-m). Front Terminal Batteries: 160 in.-lbs (M8) or 110 in.-lbs (1/4-20)

UPS12-1005PLMF OPERATING ENVIRONMENT

  • Indoor
  • Outdoor Controlled

UPS12-1005PLMF COMPLIANCE

  • TAA Compliant
  • Complies with UL1778, 924, 1989, and 94 V-2, BS6290-4, IEC-896-2

AVAILABLE MODELS

Power Storage Solutions Engineering Services for Pure Lead Max

Our engineering team can help you power your network. Power Storage Solutions offers the most extensive line of DC Power Products and Engineering Services to ensure a high reliability and quality for powering wireless networks. Power Storage Solutions provides integrated solutions for Broadband, iDAS, oDAS, Microwave, Cellular, and Land Mobile applications. Power Storage Solutions designed DC power systems have earned a reputation of high reliability and quality.

Power Storage Solutions engineers solutions for 12V, 24V, and 48V DC Power solutions include DC Power Systems, Hot Swap Rectifiers, Power Supplies, DC-DC Converters, DC-AC Inverters, DC Distribution Panels, DC Power Conditioners, DIN Rail DC UPS, DIN Rail Power Supplies, and Installation Accessories.  We can also provide additional battery backup for extended run time with lithium, lead acid and NiCd solutions.

Power Storage Solutions Installation and Service for Pure Lead Max

We understand your operations are heavily reliant on your DC Power Products. Our experience and our focus is to know the DC Power equipment and their implication for your operation. To determine the perfect solution, we will partner with you, analyze your critical power needs, and construct the backup power solution that will perform as designed.  Power Storage Solutions powers essential equipment for network communications, telecom, and public safety, providing dependable solutions for both indoor and outdoor applications.

Routine maintenance ensures your equipment stays reliable, improving your overall performance, and extending their useful life. Service plans allow customers to be proactive; providing opportunity to detect potential points of failure preventing expensive problems.

When ordering new batteries, also remember to properly recycle your old lead batteries. Federal and state regulations require lead-acid batteries be recycled. Power Storage Solutions’ nationwide service organization can arrange pickup, transportation, and recycling at any one of our company affiliated smelters. Click Here for More Information

For a more in-depth look this product, or related products in this line, please visit the Pure Lead Max Interactive Portal.

Additional Information

Weight 127 lbs
Brand

C&D

Equipment

DC POWER

Market

Telecom

Ready to Order?