KCT-270 (Calcium) / KT-270 (Antimony) FLOODED C&D BATTERIES
KCT-270 (Calcium) / KT-270 (Antimony) C&D flooded batteries are engineered to provide superior performance and reliability over the life of the product. These batteries are designed using proprietary techniques and quality components and materials for reduced maintenance and extended battery life. The C&D KCT-270 (Calcium) / KT-270 (Antimony) flooded batteries are high-performance, space-saving batteries for telecom applications.
KCT-270 (Calcium) / KT-270 (Antimony) FEATURES AND BENEFITS
- Capacities from 270-720 Ampere-hours
- Electrical testing (capacity test) on every cell prior to shipping assures performance of every battery upon delivery.
- Proprietary vacuum-assisted, bottom-pour, positive-grid casting assures void-free grid quality resulting in 20 year service life.
- Waterbath charging results in consistently formed plates for reliable performance out of the box (no cycling required in the field).
- Suspended positive plates permit free growth without pressure on jar and cover.
Safe Operation
- Standard flame-retardant covers enhance battery plant safety with self-extinguishing properties, LOI>32%, UL 94V-0.
- Low-evaporation, flame-arrester vent to extend watering intervals and prevent external sparks from reacting with the hydrogen inside the cell.
Cost Savings
- Transparent container allows visual inspection of plates.
- Soft rubber post seal minimizes stress on post reducing maintenance requirements.
- Computer controlled heli-arc welded post seals result in consistent and reliable seals for less maintenance and longer product life.
KCT-270 (Calcium) / KT-270 (Antimony) SPECIFICATIONS
- Plate Dimensions (Height, Width, Thickness)
- Positive 11.38 in (289 mm) 8.75 in (222 mm) 0.312 in (7.9 mm)
- Negative Thickness 11.38 in (289 mm) 8.75 in (222 mm) 0.210 in (5.30 mm)
- Outside Negative Thickness 11.38 in (289 mm) 8.75 in (222 mm) 0.120 in (3.10 mm) - Electrolyte height above plates 2.06 in (52 mm)
- Sediment Space 0.75 in (19 mm)
- Electrolyte @ 77˚F (25˚C) Sulfuric acid, 1.215 specific gravity nominal
- Recommended Float voltages 2.17 - 2.22 volts per cell (calcium); 2.15-2.18 volts per cell (antimony)
- Container Thermoplastic, transparent. (SAN)
- Cover High-impact, flame-retardant thermoplastic (PVC), with tongue-and-groove seal. Flammability ratings: UL 94-V0; LOT>32; ASTM D-635 self-extinguishing
- Separator Microporous with fibrous retaining mat
- Safety Vent Systems Flame-arrester type
- Terminals Two, 1-in (25 mm) square posts with 2 cross-bolt holes.
- Withdraw Tubes, Optional Two per cell. (Add ‘T’ to CW number)
- Optional Container Transparent, flame-retardant polycarbonate. Flammability ratings: UL 94-HB; PVC available for KCT-540 only
KCT-270 (Calcium) / KT-270 (Antimony) APPLICATIONS
• Telephone Central Offices
• Mobile Telephone Switching Office
• Cable Head End Sites
• Fiber Optic Regenerator Sites
• Microwave Repeater Sites
• Telephone & Internet Network Nodes
Power Storage Solutions Installation and Service for KCT-270 (Calcium) / KT-270 (Antimony)
We utilize C&D Powercom Battery Selection Application to quickly calculate many values essential for the proper selection of standby battery products We provide expert sizing analysis you need to properly size and select the proper battery. Let our Battery Sizing Specialist ensure you select the correct product.
This includes the ability to:
• Select batteries based on complex step loads and generate IEEE-485 Sizing Work Sheets.
• Select batteries based on constant current loads.
• Select batteries based on constant power loads.
• View and customize rating tables.
• Perform battery run time analysis.
Power Storage Solutions Installation and Service for KCT-270 (Calcium) / KT-270 (Antimony)
We understand your operations are heavily reliant on batteries for backup power. Our experience and our focus is to know the batteries and their implication for your operation. To determine the perfect solution, we will partner with you, analyze your critical power needs and construct the backup power solution that will perform as designed.
Routine maintenance ensures your equipment stays reliable, improving your overall performance and extending their useful life. Service plans allow customers to be proactive; providing opportunity to detect potential points of failure preventing expensive problems.
When ordering new batteries, also remember to properly recycle your old lead batteries. Federal and state regulations require lead-acid batteries be recycled. Power Storage Solutions’ nationwide service organization can arrange pickup, transportation to and recycling at any one of our company affiliated smelters. Click Here for More Information
For More Information from C&D Technologies Website: KCT/KT
Additional Information
Weight | 74 lbs |
---|---|
Equipment | Batteries |
Battery Model | KCT/KT |
Market | Telecom |
Brand | C&D |
Length | 3.62 |
Width | 10.44 |
Height |