EnerSys 2DX-29 DATASAFE® DX BATTERIES
The DataSafe® 2DX-29 batteries range of flooded lead-calcium flat plate batteries has been designed for use in UPS applications, more specifically large data centers, which demand the highest levels of security and reliability. The reliability of the DataSafe® 2DX-29 as a leading high rate performance battery is backed by 20+ years of experience in the marketplace.
The DataSafe® DX is an economical multi-cell lead-calcium flat plate battery. Multi-cell construction requires fewer units, resulting in lower installation cost. While optimizing the space available in the battery room, it delivers superior performance making the DataSafe® DX a superlative cost-effective battery.
The DataSafe® DX battery features the Slide-Lock™ post seal design, bolted tin-plated copper connectors, optimal grid design, heavy duty plate lug and strap, and dual lug design, which make this battery ideal for high rate applications.
2DX-29 DATASAFE® FEATURES AND BENEFITS
• Capacity range 0.626 - 5.446 kW per cell• Calcium alloy grids for lowest water loss, resulting in lowest maintenance costs
• Suitable for Uninterrupted Power Supply (UPS) and switchgear applications
• Multi-cell constructions
• Cover made from flame retardant PVC
• Container made from Styrene Acrylonitrile (SAN); optional flame retardant Polycarbonate (PC)
2DX-29 DATASAFE® CONSTRUCTION
• Plate thickness: Positive 0.20 in (5.0 mm); Negative 0.12 in (3.1 mm)
• Plate suspension type: Positive Bridge hung; Negative Bottom supported
• Cover - Flame retardant PVC, UL94- VO/L.O.I. 28%
• Container - SAN or optional flame retardant PC
• Electrolyte over plates 2.88 in. (73.1mm)
• Sediment space 1.04 in. (26.4 mm)
• Long life Slide-Lock™ post seal design
• Specific gravity 1.215 standard; 1.250 (B) available upon request
2DX-29 DATASAFE® INSTALLATION AND OPERATION
• Float voltage settings (1.215) - Acceptable min/max 2.17/2.26 Vpc recommended average - 2.21 v/c @ 77˚F (25˚C); Float voltage settings (1.250): Acceptable min/max 2.21/2.30 Vpc recommended average = 2.25 v/c @ 77˚F (25˚C)
• Vent type - Flame Arrestor, Fused Alumina
• Bolt Connectors - 316 Stainless Steel, English measure, Hex-head
• Intercell connectors - Tin plated copper, optional lead plated copper
2DX-29 DATASAFE® STANDARDS
• The management systems governing the manufacture of this product are ISO 9001:2008 and ISO 14001:2004 certified
• Available testing to IEEE 450 standards as well as customer specific applications
Power Storage Solutions Installation and Service for 2DX-29 DataSafe®
We understand that data centers are heavily reliant on batteries for backup power. We also understand that batteries must be redundant and if only one battery in your UPS configuration is not performing; it compromises your overall backup power. Our experience and our focus is to know the batteries and their implication for your operation. We will partner with you, analyze your critical power needs and construct the backup power solution that will perform as designed
We can remove and recycle your old battery system then install, properly set up and test your new system. We have been installing stationary batteries for over 20 years. We have the experience, equipment and capabilities to safely perform this type of work
Routine maintenance ensures your UPS equipment stays reliable, improving your UPS’s overall performance and extending their useful life. Service plans allow customers to be proactive; providing opportunity to detect potential points of failure preventing expensive problems.
When ordering new batteries, also remember to properly recycle your old lead batteries. Federal and state regulations require lead-acid batteries be recycled. Power Storage Solutions’ nationwide service organization can arrange pickup, transportation to and recycling at any one of our company affiliated smelters. Click Here for More Information
For More Information from EnerSys Website: EnerSys Datasafe DX
Additional Information
Weight | 632 lbs |
---|---|
Brand | Enersys |
Battery Model | DataSafe DX |
Equipment | Batteries |
Market | UPS-Data Centers |