EnerSys 2CX-13M DATASAFE® CX BATTERIES
FEATURING AN ECONOMICAL MULTI-CELL FLAT PLATE DESIGN AND FOOTPRINT, DATASAFE® 2CX-13M BATTERIES PROVIDE EXCELLENT SHORT DURATION DISCHARGE RATES, MAKING THEM A RELIABLE, COST-EFFECTIVE CHOICE FOR UNINTERRUPTIBLE POWER SUPPLY (UPS) AND SWITCHGEAR APPLICATIONS.
The DataSafe® CX-M battery is an economical multi-cell flat plate battery. The CX-M unit is optimized for high performance and provides excellent short duration discharge rates.
The DataSafe CX-M battery now features the Slide-Lock™ post seal design. The DataSafe CX-M battery features a larger copper insert in the Slide-Lock post. The number of plates and plate thickness are
optimized with respect to the available electrolyte ensuring maximum performance during short duration discharges.
The DataSafe CX-M battery was designed for easier maintenance since all the posts and connectors reside above the cell cover; maintenance routines, including individual cell monitoring and intercell resistance measurements are simplified. The economical design and footprint, combined with Slide-Lock post and excellent performance in short duration discharges makes this an ideal battery in UPS and switchgear applications
2CX-13M POWERSAFE® FEATURES AND BENEFITS
• Slide-Lock™ post seal design
• Calcium alloy grids for lowest water loss, resulting in lowest maintenance costs
• Lead plated copper posts provide high 1-minute rates
• 100% Initial capacity
• 20 year life expectancy in floating applications where high ambient temperature is not a factor
• The number of plates and the plate thickness have been optimized with respect to the available free electrolyte to ensure maximum performance during short duration discharges without sacrificing component integrity
2CX-13M CONSTRUCTION
• Plate thickness: Positive: 0.20 in/5.1 mm Negative: 0.14 in/3.6 mm
• Plate dimensions: Height Width Positive: 7.75 in/197 mm 8.00 in/203 mm Negative: 7.75 in/197 mm 8.00 in/203 mm
• Plate suspension type: Positive: Bottom supported Negative: Bottom supported
• Container: Styrene Acrylonitrile Copolymer, optional PC
• Cover: Made from flame retardant PVC, (UL94-VO/L.O.I. 28%)
• Separators: Microporous plastic
2CX-13M Installation and Operations
• Installation services and preventative maintenance packages available
• Bolt connectors: Stainless steel, Standard English measure, Hex-Head
• Inter-unit connectors: Tin-plated copper, Optional lead-plated copper
• Electrolyte over plates: 2.38 in/60.5 mm
• Vent type: Flame Arrestor, Fused Alumina
2CX-13M STANDARDS
• Manufactured in EnerSys® production facilities certified to ISO™ 9001: 2008
• Manufactured in EnerSys production facilities certified to ISO 14001: 2004
• Available testing to IEEE 450 standards as well as customer specific applications
NOTE: All inter-cell, inter-tier, inter-step, end-to-end inter-rack, back-to-back inter-rack connectors, terminal lugs, and terminal plates are included with every battery. Across-aisle inter-rack connectors are not included
Power Storage Solutions Installation and Service for 2CX-13M
We understand that data centers are heavily reliant on batteries for backup power. We also understand that batteries must be redundant and if only one battery in your UPS configuration is not performing; it compromises your overall backup power. Our experience and our focus is to know the batteries and their implication for your operation. We will partner with you, analyze your critical power needs and construct the backup power solution that will perform as designed.
We can remove and recycle your old battery system then install, properly set up and test your new system. We have been installing stationary batteries for over 20 years. We have the experience, equipment and capabilities to safely perform this type of work.
Routine maintenance ensures your UPS equipment stays reliable, improving your UPS’s overall performance and extending their useful life. Service plans allow customers to be proactive; providing opportunity to detect potential points of failure preventing expensive problems.
When ordering new batteries, also remember to properly recycle your old lead batteries. Federal and state regulations require lead-acid batteries be recycled. Power Storage Solutions’ nationwide service organization can arrange pickup, transportation to and recycling at any one of our company affiliated smelters. Click Here for More Information
For More Information from EnerSys Website: EnerSys Datasafe CX-M
Additional Information
Length | 12.2 |
---|---|
Width | 9 |
Height | |
Brand | Enersys |
Battery Model | Datasafe CX |
Equipment | Batteries |
Market | UPS-Data Centers |