12HX1000F-FR DATASAFE®

EnerSys 12HX1000F-FR DATASAFE® HX BATTERIES

The 12HX1000F-FR DataSafe® battery systems offer more power in a smaller space than top terminated 12V UPS batteries. Ideal for space restricted applications, the 12HX1000F-FR occupies up to 6% less space than top terminated batteries and utilizes 33% less strings and connections.Equipped with Valve Regulated Lead Acid (VRLA) technology,
12HX1000F-FR batteries feature unmatched energy density designed for the most demanding mission-critical applications. Rated at 100% initial capacity at initial discharge, 12HX1000F-FR batteries provide unmatched security and reliability for mission-critical systems. The 12HX1000F-FR DataSafe® batteries feature full front access terminals make the batteries easy to install, while easy-to-access terminals and no slide out tray simplify maintenance. 12HX1000F-FR batteries can also accommodate monitoring systems and scale easily to large capacity UPS systems.

12HX1000F-FR DATASAFE® SPECIFICATIONS

• Normal operating temperature range -22°F (-30°C) to 122°F (50°C)
• Float charging voltage 2.25-2.28 Volts per cell at 77°F (25°C)
• DataSafe® HX batteries can be stored for up to six months at 77°F (25°C) before a freshening charge is required. At higher temperatures this time interval will be reduced
• Torque specification: 160 IN LB (18 Nm)

12HX1000F-FR DATASAFE® FEATURES AND BENEFITS

• Smaller footprint per kilowatt vs. top terminated 12V batteries
• 6% system space savings vs. 12V top terminal systems
• True front terminal front access installation
• Scales easily with expanding large capacity UPS systems
• 1000 WPC design requires fewer parallel strings
• Easy terminal access simplifies maintenance
• No costly slide out trays required

12HX1000F-FR DATASAFE® APPLICATIONS

• Industrial UPS
• Alarm & Security Systems
• Emergency Lighting
• Public Safety Networks
• Surveillance & Security
• Traffic & Intelligent Transportation Systems (ITS)
• Data Centers

12HX1000F-FR DATASAFE® CONSTRUCTION

• Insulating covers and voltmeter probe access enhance safety and simplify maintenance routines
• Polypropylene strap handle simplifies installation, removal and replacement
• Self-resealing, flame-arresting vents prevent ingress of atmospheric oxygen
• Tin-plated copper busbars reduce connection resistance to enhance power delivery from the battery system
• Plasma welded current conductors are a high current, low resistance method of construction similar to our ODYSSEY® Extreme Series™ and Performance Series™ batteries
• True front terminal reduces connection points and maintenance checks
• Thick-wall plastic containers, highly resistant to shock and vibration. Flame retardant material is the standard offering
• Low resistance microporous Absorbed Glass Mat (AGM) separator. The electrolyte is absorbed within this material
• FR-ABS case and cover designed to resist bulging

12HX1000F-FR DATASAFE® STANDARDS

• UL listing – File No: MH12544
• The management systems governing the manufacture of this product are ISO 9001 and ISO 14001 certified

Power Storage Solutions Installation and Service for 12HX1000F-FR DATASAFE®

We understand that data centers are heavily reliant on batteries for backup power. We also understand that batteries must be redundant and if only one battery in your UPS configuration is not performing; it compromises your overall backup power. Our experience and our focus is to know the batteries and their implication for your operation. We will partner with you, analyze your critical power needs and construct the backup power solution that will perform as designed

We can remove and recycle your old battery system then install, properly set up and test your new system. We have been installing stationary batteries for over 20 years. We have the experience, equipment and capabilities to safely perform this type of work

Routine maintenance ensures your UPS equipment stays reliable, improving your UPS’s overall performance and extending their useful life. Service plans allow customers to be proactive; providing opportunity to detect potential points of failure preventing expensive problems.

When ordering new batteries, also remember to properly recycle your old lead batteries. Federal and state regulations require lead-acid batteries be recycled. Power Storage Solutions’ nationwide service organization can arrange pickup, transportation to and recycling at any one of our company affiliated smelters. Click Here for More Information

For More Information from EnerSys Website: EnerSys Datasafe HX

Additional Information

Weight 33.6 lbs
Brand

Enersys

Battery Model

Datasafe HX

Equipment

Batteries

Market

UPS-Data Centers

Length

21.6

Width

6.1

Height